What was found
#2 ENGINE HIGH PRESSURE SHUTOFF VALVE LOCKOUT INOP (HEILCOIL DAMAGE). GROUNDED - YES. CW EA MAX-36EA-25932 MAX HIGH PRESSURE SHUTOFF VALVE MANUAL LOCK HELICOIL INSERT INSHOP REPAIR. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
#2 ENGINE HIGH PRESSURE SHUTOFF VALVE LOCKOUT INOP (HEILCOIL DAMAGE). GROUNDED - YES. CW EA MAX-36EA-25932 MAX HIGH PRESSURE SHUTOFF VALVE MANUAL LOCK HELICOIL INSERT INSHOP REPAIR. OK FOR SERVICE.