What was found
WHILE PERFORMING TRANSIT CHECK FOUND 2" CRACK OB SIDE AFT ENDGE 3/4" OB SIDE FWD EDGE 1 1/2" CRACK IB SIDE AFT EDGE 3/4" CRACK IB SIDE FWD EDGE. ALL CRACKS LOCATED NEAR TOP OF APU SHROUD DRAIN MAST. GROUNDED - YES. REMOVED APU FUEL FEED LINE SHROUD MAST REF AMM 28-25-07 53124REPLACED APU FUEL FEED LINE SHROUD DRAIN MAST REF AMM 28-25-07-420-801REF L/P 60911696 FOR DRAIN MAST STENCIL MARKING DEFERRALREF L/P 60911697 FOR DRAIN MAST PAINT DEFERRAL.