As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT WET AREA FLOOR BEAM AT -Y765 CORRODED AT FR66-FR68 GROUNDED - YES. REMOVED AND REPLACED AFT WET AREA FLOOR BEAM PN: D5347219320400 PO: 1071806.4 IAW AIRBUS DWG: D53472143, A320-SRM-51-72-11, A320-SRM-51-42-11 FLOOR BEAM FOUND TO BE OUT OF LIMITS ORIGINAL THICKNESS .150" MINIMUM REMAINING .114" .036" LOSS L=3.1" W=2.12" IAW A320-SRM-53-41-14-283-004 DOT REMOVED TOOL# T8493K CAL DUE 12/07/2023