What was found
"MAINT" LIGHT ON AFT OVERHEAD PANEL ILLUMINATED AFTER LANDING. GROUNDED - YES. (RESOLVED ON W/O: 1973312 TASKCARD: N/R-00003 ) REF TSR 715091 PERFORMED ODMS INSPECTION REF AMM 79-00-00-210-804. INSTALLED ODMS SENSOR REF AMM 79-21-12/401. NO DEFECTS NOTED. LEAK CHECK GOOD. PERFORMED IFIM 79-21-00-810-803 STEPS B. (1-7). NO DEFECTS NOTED. OMF MESSAGE NOT ACTIVE. MAINT LIGHT OFF. MEL 79-21-01A REMOVED. PLACARD REMOVED. SEAMC DARWIN AUTHORIZED.