What was found
L PACK LIGHT ILLUMINATED SINGLE CHANNEL FAULT. GROUNDED - YES. REF FIM 21-53 TASK 821, PERFORMED PZTC 1 + 2 BITE, PZTC 1 HAD RAM AIR ACTUATOR FAULT LIGHT. REF FIM 21-62 TASK 837 PERFORMED OPS TEST OF PACK 1, OPS TEST GOOD, L/H PACK LIGHT NOT ILLUMINATED, PERFORMED PZTC 1 (AND 2) BITE AGAIN, NO FAULTS, PZTC 1 FAULT CLEARED AND DID NOT RETURN, DURING BITE "VERIFY" L/H RAM AIR ACTUATOR OPS NORMAL. PER FIM THIS WAS AN INTERMITTENT FAULT. REMOVES CN: 20002587 SEAMC JOE NOTIFIED. THIS CLEARS MEL 21-32B.