What was found
APU BLEED INOP - HAS HISTORY FOR THE SAME ON 10/13/23. GROUNDED - YES. (RESOLVED ON W/O: 1975133 TASKCARD: N/R-00001 ) C/W INITAL EVAL AND FAULT ISOLATION FOR FC 49-52192, IGV ACTUATOR LVDT SHOW CIRCUIT FAILUIRE. NO FAULTS NOTED DURING APU WIRING AND IGV ACTUATOR RESISTANCE CHECKS. DUE HISTORY RECOMMEND REPLACING THE IGV ACTUATOR. REF FIM 49-52 TASK 806. J. ASHBECK 23714 10/29/2023. REMOVED & REPLACED IGN ACTUATOR PER AMM 49-52-12 OPP CHECK GOOD NO LEAKS NOTED AT THIS TIME BITE CHECK CLEAR AT THIS TIME. THIS CLEARS MEL 49-7C. PLACARDS REMOVED SEAMC WILL NOTIFIED.