What was found
R/H FWD ENTRY DOOR R1 LOWER CUTOUT AT GIRT BAR PLATE ATTACHMENT EVEDENCE OF CORROSION FOUND. WL HTTPS:// GROUNDED - YES. REMOVED CORROSION. REMAINING MAT. THICKNESS .203 FOUND TO BE WITHIN LIMITS AS PER A320 SRM 53-11-14-283-005 HI FRQ AS PER NTM 51-10-08. APPLIED PROTECTIVE TREATMENTS AS PER A320 SRM 51-21-11. TOP COATED AS PER A320-SRM 51-75-12 MAX ALLOWED MUST BE GREATER THAN .177 REMAINIG FOUND TO BE WITHIN LIMITS REF A320 SRM 53-11-4-283-005 THIS IS A CAT B REPAIR INSPECTION THRESHOLD 60,000FC FH NOT RELEVANT INSPECTION INTERVALS AND METHOD TBD REF A320 SRI 53-11-14-205-001