What was found
FWD L/H ENTRY DOOR LOWER CUTOUT CORROSION FOUND ON GIRT BAR PLATE FITTING GROUNDED - YES. REMOVED CORROSION. 4EACH HOLES. REMAINING MAT THICKNESS .153 FOUND TO BE WITHIN LIMITS AS PER A320 SRM 53-11-14-283-005, HFEC PERFORMED AS PER NTM 51-10-08. APPLIED PROTECTIVE TREATMENTS AS PER A320 SRM 51-21-11. TOP COATED AS PER A320 SRM 51-75-12. HOLE 1 REMAINING .153 HOLE 2 REMAINING .192 HOLE REMAINING .153 HOLE #4 REMAINING .159 MAX ALLOWED MUST BE GREATER THAN .1476 FOUND TO BE WITHIN LIMITS REF A320 SRM 53-11-14-283-005 THIS IS A CAT B REPAIR INSPECTION THRESHOLD 60,000 FC FH NOT RELEVANT INSPECTION INTERVAL AND METHOD TBD REF A320 SRI 53-11-14-205-001