What was found
R2 DOOR SILL FR68 NUTPLATE LOCATION CORRODED GROUNDED - YES. REPAIRED R2 DOOR SILL AT FR68, S23R, -Y1732 IAW A320 SRM 53-41-14-300-001 REPAIR PRINCIPLE 7. (REMOVED CORROSION AT FR68 DOOR SILL AREA K, ORIGINAL MATERIAL 0.374", REMOVED 0.051" REMAINING MATERIAL 0.323", FOUND AREA TO BE WITHIN LIMITS IAW A320 SRM 53-41-14-283-002, REMOVED CORROSION AT FR68 DOOR SILL NUT PLATES AREA CODE A, ORIGINAL MATERIAL 0.063, REMOVED 0.050", REMAINING MATERIAL 0.013", FOUND TO BE OUT OF LIMITS IAW A320-200 SRM 53-41-14-283-002.) CATEGORY A REPAIR