What was found
MAIN CABIN, FLOOR STRUCTURE UNDER L-1 DOOR AT AFT GIRT BAR RECIEVER STUDS CORRODED GROUNDED - YES. REMOVED CORROSION ON 3EA FASTENER HOLES ON L1 DOOR SILL. AFT GIRT SHOE/SILL BEAM SURFACE FWD O/B HOLE, L=1.3, W=.900, ORIGINAL THICKNESS .197, REMOVED .020, REMAINING .177. FWD I/B HOLE L=1.3, W=1.3, ORIGINAL THICKNESS .197, REMOVED .021, REMAINING .176. AFT O/B HOLE L=1.6, W=1.3, ORIGINAL THICKNESS .197, REMOVED .028, REMAINING .169 FOUND TO BE WITHIN LIMITS IAW A320 SRM 53-11-14-283-005 REV. 147 FIG 1 SHEET 2. REWORKED AREA TOUCHES ALL 3EA FASTENER HOLES. ACCOMPLISHED SPOTFACE IAW A320 SRM 53-11-14-283-005 REV 197 FIG 1 SHEET 2 O/B FWD HOLE DIAMETER IS .25, DEPTH .025, REMAINING MATERIAL AT SPOTFACE AREA IS .157. O/B AFT HOLE DIAMETER IS .250, DEPTH .030, REMAINING MATERIAL AT SPOTFACE AREA IS .167. INSTALLED 3EA REPAIR WASHERS AND 4EA NEW FASTENERS IAW A320 SRM 53-11-14-283-005 REV 147 FIG 1 SHEET 2. CAT B REPAIR INSPECTION THRESHOLD 60,000 FC/FH