As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R2 DOOR AFT GIRT BAR FITTING HAS EVIDENCE OF CORROSION UNDER PLATE. GROUNDED - YES. REMOVED AND REPLACED R2 DOOR SILL UNDER PLATE OF R2 DOOR AFT GIRT BAR FITTING AT STR 23R BETWEEN FR65R TO FR69R IAW SRM 51-42-11-001/001 AND SRM 51-72-911-002 REV. 147.