What was found
FLOOR STRUCTURE BETWEEN C68 AND C70 UNDER FLOOR PANEL 261PF HAS CORROSION GROUNDED - YES. REMOVED AND REPLACED FLOOR BEAM AT FR66 TO FR70. Y= -765 TO Y= -765 IAW A320 SRM 51-72-11-911-001 AND SRM 51-72-911-002
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR STRUCTURE BETWEEN C68 AND C70 UNDER FLOOR PANEL 261PF HAS CORROSION GROUNDED - YES. REMOVED AND REPLACED FLOOR BEAM AT FR66 TO FR70. Y= -765 TO Y= -765 IAW A320 SRM 51-72-11-911-001 AND SRM 51-72-911-002