What was found
L/H INBD. FLAP LOWER TRAILING EDGE WEDGE, MIDDLE CLUSTER REQUIRES REPAIR. GROUNDED - YES. REMOVED 9.4" X 10.5" DAMAGED LH INBD FLAP LWR SKIN & CORE 83" FROM INBD EDGE / 5.5" FROM TE IDENTIFIED AS MIDDLE CLUSTER & REPAIRED IAW A320-200 SRM 57-52-00-300-093 REV.147. REMOVED & INSTALLED 14EA FASTENERS, APPLIED FILLET SEAL TO DOUBLER IAW A320-200 SRM 57-52-00-300-093 REV.147. RESTORED FINISH IAW A320-200 SRM 57-52-00-300-093 REV 147 & A320-200 SRM 51-75-12-911-002 REV.147. FH-48753:06, FC-18421, WV-015. ALL LOCATED IN ZONE 2. PART# D5757065003600 S/N TB-13040. THIS IS A PERMANENT CATEGORY A REPAIR