What was found
AFT PIT FLOOR RAIL LBL 8 SPLICE CHANNEL AT STA 727I+4 IS CORRODED. GROUNDED - YES. FABRICATED AND REPLACED AFT PIT FLOOR RAIL SPLICE LBL 8 STA 727I+4 IAW 737-900 SRM 51-40-02-0G-0 & DWG 146A7506W- .5" O- .070" R- .084" L- 1" D- .016".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FLOOR RAIL LBL 8 SPLICE CHANNEL AT STA 727I+4 IS CORRODED. GROUNDED - YES. FABRICATED AND REPLACED AFT PIT FLOOR RAIL SPLICE LBL 8 STA 727I+4 IAW 737-900 SRM 51-40-02-0G-0 & DWG 146A7506W- .5" O- .070" R- .084" L- 1" D- .016".