AFT PIT RBL 3 FLOOR RAIL SPLICE AT STA 727I+4 IS CORRODED. GROUNDED - YES. FABRICATED AND REPLACED AFT PIT FLOOR RAIL SPLICE RBL 3 STA 727I+4 IAW 737-900 SRM 51-40-02-0G-0 & DWG 146A7506W- .5" O- .070" R- 0 L- 1" D- .070".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT RBL 3 FLOOR RAIL SPLICE AT STA 727I+4 IS CORRODED. GROUNDED - YES. FABRICATED AND REPLACED AFT PIT FLOOR RAIL SPLICE RBL 3 STA 727I+4 IAW 737-900 SRM 51-40-02-0G-0 & DWG 146A7506W- .5" O- .070" R- 0 L- 1" D- .070".