What was found
L2 DOOR LOWER SILL BEAM CENTER ATTACH FITTING HAS EXFOLIATION. GROUNDED - YES. REMOVED AND REPLACED NEW SHAPE SILL (CORNER FITTING) AT L2 DOOR SILL BEAM IAW A320 SRM 51-42-11/001 AND 51-72-11-911-001 REV 117.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L2 DOOR LOWER SILL BEAM CENTER ATTACH FITTING HAS EXFOLIATION. GROUNDED - YES. REMOVED AND REPLACED NEW SHAPE SILL (CORNER FITTING) AT L2 DOOR SILL BEAM IAW A320 SRM 51-42-11/001 AND 51-72-11-911-001 REV 117.