What was found
AFT CARGO BAY FLOOR JUST INSIDE DOOR NEAR AFT DOOR FRAME CORRODED AT LOCK FASTENER, JUST FORWARD OF STATION C5624 INCHES RIGHT OF CENTERLINE GROUNDED - YES. REMOVED 3EA FASTENERS IAW A320 SRM 51-42-11/001/REV 148-01. REMOVED CORROSION AND FOUND WITHIN LIMITS IAW SRM 53-41-49-283-004 REV 148- 01FEB2024. ACCOMPLISHED DVI AND HFEC INSPECTIONS IAW A320 SRM 53-41-49-283-004 REV 148-01. ALODINED AND PRIMED IAW A320 SRM 51-21-11/001 REV 148- 01FEB2024 TOP COAT PAINT IAW SRM 51-23-11/001 REV 148- 01FEB2024. CAT A FH 33908:24 FC 11,488, MSN 5179. SEE ATTACHED PHOTO FOR DAMAGE MAP-OUT WV15 INSTALLED 3EA FASTENERS IAW A320 SRM 51-42-11/001 REV. 148- 01FEB2024