FWD WET AREA STA 344 FLOOR BEAM HAS CORROSIONAT RBL 5. GROUNDED - YES. REMOVED DAMAGE WITH SURFACE BLEND FOUND TO BE OUT OF LIMITS REPAIRED FLOOR BEAM FROM STA 344 RBL 5 IAW B737-900 SRM 53-10-51-2R-9W= 1 O= .175 R= .131 L= 1 D= .044.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.