What was found
FOUND DENT ON R/H SIDE OF FUS. AT STA 905 +9" 3" BELOW STR 17R GOUGE IN CENTER OF DENT. GROUNDED - YES. (RESOLVED ON W/O: 1996489 TASKCARD: N/R-00001 ) DENT ON R/H SIDE OF FUSELAGE AT STA 905+9" 3" BELOW STR 17R REPAIRED IAW EA 800-53EA-26862. THIS IS A CATEGORY B REPAIR AND A 8110-3 WAS ISSUED ON 04-11-2024 AND A NEW 8110-3 REQUIRED WITHIN 18 MONTHS OF THIS DATE. SEAMC AARON NOTIFIED CLEARS NOT DEFERAL.