As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD LOWER R1 DOOR JAMB STUB FRAME IS CRACKED AT FLOOR LEVEL. GROUNDED - YES. REPAIRED STUB FRAME FWD LOWER CORNER OF R1 DOOR CUTOUT IAW ALASKA EA # 900-53EA-26850 REV. 00 INSPECTION REQUIREMENTS MUST BE ISSUED FINDING COMPLIANCE WITH 14CFR25.571 (B) PRIOR TO THE INSPECTION THRESHOLD OF 50,000 TOTAL FLIGHT CYCLES.