As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CABIN, L/H AFT ENTRY DOOR I/B TOP 'DOOR STOP FITTING' HAS BARE (METAL.GOUGE). DOT#Z211 STREAMER IIS ATTACHED. GROUNDED - YES. EVALUATED STOP FITTING AND FOUND DAMAGE TO THE BUSHING, DAMAGE TO BUSHING IS NOT PERMITTED AND FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 52-10-90-1A-1. REMOVED AND REPLACED STOP FITTING ASSY IAW BAC DWG 147A6116 REV- AND B737-800 SRM 51-40-02.