What was found
UPON REMOVAL OF AFT PIT DOOR SURROUND FWD SHIELD, FOUND ATTACHING ANGLE UNDERNEATH TO HAVE MULTIPLE AREAS OF CORROSION. GROUNDED - YES. REMOVED CORR. FROM AFT PIT DOOR SURROUND FWD SHIELD ATTATCHED ANGLE ORIG THICKNESS .050. I.A.W. B737-800 SRM 53-60-15 MAT. LOSSED .012 REMAINING THICKNESS .038 FOUND TO BE OUT OF LIMITS I.A.W. B737-800 SRM 53-60-15 TOOL#T8224L DUE 20NOV/24. REMOVED AND REPLACED ATTATCHED FITTING I.A.W. B737-800 SRM 51-40-02 AND BOEING DWG# 146A8123 REV:-. LOCATED, DRILLED AND DEBURRED NEW ATTATCHED ANGLE I.A.W. B737-800 SRM 51-40-05.