What was found
950(RH HAND SIDE) INTERCOSTAL / FLOOR SUPPORT HAS CORROSION AT HOLE. GROUNDED - YES. BLENDED CORROSION ORINGINAL THICKNESS, FROM PART, .080, MAT LOSS .018, NEW THICKNESS .062 THERE ARE NO SRM ALLOWABLE LIMITS , REMOVED DAMAGE SUPPORT AND INSTALLED P# 147A5676-6 PO# 1092248.1 PER B737-800 SRM 51-40-02 PER AIPC 53-52-51 AND DWG 147A5650.