What was found
L-2 DOOR SILL CORRODED AT NUTPLATES 2 INCHES INBOARD OF AFT GIRT BAR FITTING. GROUNDED - YES. REMOVED CORROSION AT 2EA FASTENER HOLES. FWD FAST. AREA, ORIGINAL THICK-.315", MAT:REMOVED .004", REMAINING THICK-.311". AFT FAST. HOLE AREA, ORIGINAL THICK-.315", MAT. REMOVED. 010", REMAINING THICK-.305". FOUND TO BE WITHIN LIMITS IAW A320 SRM 53-41-14-300-001 REV 149-01MAY2024. APPLIED PROTECTIVE TREATMENT IAW A320 SRM 51-21-11/001 AND 51-23-11/001 REV 149-01MAY2024. CATEGORY A REPAIR