What was found
AFT PIT R/H TRANSITION HAS CORROSION STA 767-727D. GROUNDED - YES. REMOVED AND REPLACED TRANSITION FROM STA 767-727D IAW B737-800 SRM 51-40-02-0G-0, AFT PIT R/H TRANSITION FROM STA 727E TO STA 727B FOUND TO BE IN LIMITS IAW B737-800 SRM 53-00-53-1A-2W= 1' O= .040" R= .035" L= 2" D= .006".