What was found
AFT WET AREA FLOOR SUPPORT ZEE ANGLE IS CORRODED AT STA 98-1006 LBL 32. GROUNDED - YES. CORROSION FOUND OUT OF LIMITS, 100% MATERIAL LOSS IAW B737-800 SRM 53-70-51-1A-1, DRILLED TO FIT NEW SUPPORT IAW B737-800 SRM 51-40-05, DOCUMENT NUMBER: 147A5700 TYPE: DWG ID: 0063 REV:-, SUPPORT INSTALLED ON N/R 47484, CUST CARD NO. G2000484 P/N 147A5710U16, PO 1093712-1.