What was found
FWD PIT, RH SHIELD PANEL CORRODED BETWEEN STA 500-500+12. GROUNDED - YES. REMOVED & REPLACED SHIELD IAW B737-700 SRM 51-40-02-0G-0 W=1.0" O=.032 R=.500 L=2.0" D=.032.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT, RH SHIELD PANEL CORRODED BETWEEN STA 500-500+12. GROUNDED - YES. REMOVED & REPLACED SHIELD IAW B737-700 SRM 51-40-02-0G-0 W=1.0" O=.032 R=.500 L=2.0" D=.032.