What was found
AFT OVERWING EXTERIOR EMERGENCY EXIT LIGHTS ON L/H + R/H SIDE INOP. GROUNDED - YES. (RESOLVED ON W/O: 2018478 TASKCARD: N/R-00001 ) REMOVED AND RELAMPED INOP OVERWING EXTERIOR LIGHTS REF AMM 33-51-04. L/H EMERGENCY LIGHTS NOW OPERABLE, R/H AFT OVERWING LIGHT AND LOWER EMERGENCY LIGHTS STILL INOP SEAMC TOD NOTIFIED. MICHAEL BUCHANAN 67948, 09/16/2024REMOVED AND REPLACED POWER SUPPLY M1695 REF AMM 33-51-06-960-806. R/H AFT OVERWING LIGHT AND LOWER R/H SLIDE LIGHT INOP. HPD 53557 09/16/2024. REPLACED NEW M1671 POWER SUPPLY & NEW BATTERY. PERFORMED INSTALLATION TEST NORMAL WDM 33-51-13-3-3. AMM 33-51-06. AMM 33-51-00. MSUN 20477 09/16/2024THIS CLEARS MEL 33-14C SEAMC PETER NOTIFIED, PLACARDS REMOVED.