What was found
R/H LAP JOINT AT STA 1016 TO STA 1088 AT STR 16 SEC 48 HAS SIGNS OF CORROSION. GROUNDED - YES. ACCOMPLISHED CATEGORY A MINOR REPAIR ON SKIN PANELS P/N 148A3331-1 AND P/N 148A3321-13 IAW EA 800-53EA-27640 REV. 00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R/H LAP JOINT AT STA 1016 TO STA 1088 AT STR 16 SEC 48 HAS SIGNS OF CORROSION. GROUNDED - YES. ACCOMPLISHED CATEGORY A MINOR REPAIR ON SKIN PANELS P/N 148A3331-1 AND P/N 148A3321-13 IAW EA 800-53EA-27640 REV. 00.