What was found
EMERGENCY LIGHT POWER SUPPLY M1676 REQUIRES REPLACEMENT. GROUNDED - YES. REMOVED AND REPLACED AND PERFORMED INSTALLATION TEST OF EMERGENCY LIGHT POWER SUPPLY M1676 PER B737-900 AMM 33-51-06-960-806 TEST GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHT POWER SUPPLY M1676 REQUIRES REPLACEMENT. GROUNDED - YES. REMOVED AND REPLACED AND PERFORMED INSTALLATION TEST OF EMERGENCY LIGHT POWER SUPPLY M1676 PER B737-900 AMM 33-51-06-960-806 TEST GOOD.