As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT SIDE STA 294.5 FLOOR SUPPORT STRUCTURE HAS CORROSION AREAS MARKED W/RED STREAMERS ATTACHED GROUNDED - YES. REOMVED CORROSION AS REQUIRED, ORIG THICKNESS IS .195", REMOVED .088", REMAINING .107", FOUND OUT OF LIMITS IAW B737-900 SRM 53-10-51. REMOVED AND REPLACED FLOOR SUPPORT IAW B737-900 SRM 51-40-02 AND BOEING DWG 141A5600 REV-.