What was found
FWD WET AREA FLOOR STRUCTURE INTERCOSTAL IS CRACKED BS312-BS328, LBL 45.6. GROUNDED - YES. REMOVED INTERCOSTAL IAW B737-900ER SRM 51-40-02. INSTALLED NEW INTERCOSTAL PER BAC DWG# 141A5400 REV- AND IAW B737-900ER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD WET AREA FLOOR STRUCTURE INTERCOSTAL IS CRACKED BS312-BS328, LBL 45.6. GROUNDED - YES. REMOVED INTERCOSTAL IAW B737-900ER SRM 51-40-02. INSTALLED NEW INTERCOSTAL PER BAC DWG# 141A5400 REV- AND IAW B737-900ER SRM 51-40-02.