What was found
FWD PIT R/H TRANSITION HAS SPOTS OF CORROSION STA 500H TO 500I. GROUNDED - YES. REPAIRED TRANSITION PANEL SUPPOR ON RH FWD CARGO COMPT. STA 500H TO 500I IAW B737-800 SRM 53-00-53-2R-5W= 1.5 O= 0.045" R= 0.037" L= 2" D= 0.008".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.