As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MULTIPLE EMERGENCY EXIT LIGHTS INOP. INTERIOR: 1. NEXT TO FIRST CLASS LAV 2. ABOVE ROW 30ABC 3. ABOVE ENTRANCE TO AFT GALLEY 4. NEXT TO L2 DOOR 5. ABOVE L2 DOOR. EXTERIOR: EMERGENCY EXIT LIGHT RIGHT OF L2 DOOR. GROUNDED - YES. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY M1673 IAW B39M AMM 33-51-06-960-803. OPS CHECK GOOD.