FLOORBOARD SPLICE CORROED STA 767. GROUNDED - YES. FABRICATED REPLACEMENT FLOOR SPLICE TEE. AT STA 767 IAW B737-900 SRM 53-60-53-01-2, SRM 51-40-05-0G-0. W= 1" O= .070 R= .000 L= 1" D= .070