What was found
WHEN TRYING TO CLOSE DOOR, F/A REPORTS THAT YELLOW GUST LOCK LEVER WON'T STAY DOWN POSITION IN ORDER TO CLOSE L1 DOOR. GROUNDED - YES. (RESOLVED ON W/O: 2055088 TASKCARD: N/R-00001 ) MIG-2C 40-0063391 INITIATED. REMOVED L1 DOOR GUIDE ARM REF AMM 52-11-21. INSTALLED L1 DOOR GUIDE ARM UP TO STEP G(1)(5) REF. AMM 52-11-21. REMOVED SECOND GUIDE ARM REF AMM, AMM 52-11-21. FOUND LOWER RADIUS LINK HOLE WITH SHARP EDGE AND WASHER CUT INTO TWO PIECES. INIT MIG-2C #40-0063392. COMPLETED INSTALLATION OF GUIDE ARM ON MIG-2C 40-0063391. CLOSED MIG-2C 40-0063391 AND 40-0063392. OPS CHECK GOOD.