What was found
AFT WET AREA FLOOR WEB STA 986-1006 RBL 24-45 HAS CORROSION. GROUNDED - YES. REMOVED DAMAGE IAW B737-900ER SRM 51-10-02, ORIGINAL THICKNESS .080, MAT REMAINING .039 PER BAC DWG# 147A5116-19 REV A FOUND OUT OF LIMITS DUE TO NOT ALLOWABLE DAMAGE LIMITS GIVEN ON SRM, REMOVED WEB IAW B737-900ER SRM 51-40-02, LOCATED & DRILLED & COUNTERSUNK NEW WEB P/N 147A5116U20 P.O. 1124266.1 PER BAC DWG# 147A5701 REV- AND IAW B737-900ER SRM 51-40-05, SRM 51-40-08, INSTALLED GALLEY MOUNTS AND FLOOR WEB PER BAC DWG# 147A5701 REV- AND IAW B737-900ER SRM 51-40-02, SRM 51-40-04.