What was found
FORWARD CARGO COMPARTMENT BILGE, FRAME TO STRINGER ATTACH ANGLE CORRODED. STA500F 6 OCLOCK. GROUNDED - YES. REMOVED DAMAGE ORIGINAL: .050, REMOVED: .008, REMAINING: .042, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGE SHEAR TIE, LOCATED AND DRILLED NEW SHEAR TIE P/N: 143A3010-145, PO: 1126330.1 AND INSTALLED SHEAR TIE, IAW SRM 51-40-02, SRM 51-40-05 AND BAC DWG 143A1231 REV: C.