What was found
FWD WET AREA FLOOR SUPPORT HAS CORROSION STA 312 TO 328 RBL 12. GROUNDED - YES. REMOVED AND REPLACED FLOOR SUPPORT AT STA 312TO 328 RBL 12 IAW B737-800 SRM 51-40-02-0G-0W= 2 O= .080 R= .066 L= 1 D= .014.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD WET AREA FLOOR SUPPORT HAS CORROSION STA 312 TO 328 RBL 12. GROUNDED - YES. REMOVED AND REPLACED FLOOR SUPPORT AT STA 312TO 328 RBL 12 IAW B737-800 SRM 51-40-02-0G-0W= 2 O= .080 R= .066 L= 1 D= .014.