What was found
FWD CARGO TRANSITION PROFILE CORRODED AT STA 500L TO 500A AND BL 25R. GROUNDED - YES. REMOVED CORROSION AS REQ IN MULTIPLE AREAS. ORIG THICKNESS IS 0.040 PER SRM 53-30-53-01-02. LOWEST MATERIAL REMOVED WAS 0.020 REMAINING THICKNESS IS 0.020. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED TRANSITION PANEL IAW SRM 51-40-02. FABRICATED REPAIR PARTS AND TRANSITION PANEL PN BAC1496444 7075-T62 PO 1131998.1 IAW SRM 53-00-53-2R-6, SRM 51-40-05 AND DWG 14347500 REV -. APPLIED PROTECTIVE TREATMENT TO PARTS IAW SRM 51-20-01. INSTALLED REPAIR PARTS AND TRANSITION PANEL IAW 51-40-02, SRM 53-00-53-2R-6 AND DWG 143A7500 REV -.