What was found
AFT WET AREA FLOORBEAM STA 986 CORRODED RBL 50. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED DAMAGE AREA IAW SRM 53-70-51-2R-6. W 2, 0 .150, R .136, L 1, D .014.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT WET AREA FLOORBEAM STA 986 CORRODED RBL 50. GROUNDED - YES. REMOVED DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED DAMAGE AREA IAW SRM 53-70-51-2R-6. W 2, 0 .150, R .136, L 1, D .014.