What was found
RIGHT HORIZONTAL STAB LOWER SKIN DAMAGED AT RIB 6 APPROXIMATELY HSS 138.7. GROUNDED - YES. EVALUATED DAMAGE AT LWR SKIN FOUND TO BE OUT OF LIMITS LENGTH=2.7", DEPTH=.041 IAW SRM 55-10-01-1A-2, FIG.103. REMOVED RT HORIZONTAL STAB. L/E PANEL & STAB. CAP IAW SRM 51-40-02. CUTOUT DAMAGED AREA AT LWR SKIN IAW SRM 55-10-01-2R-1, REPAIR 11. FABRICATED, LOCATED & DRILLED REPAIR PARTS IAW SRM 55-10-01-2R-11. APPLIED ALODINE ON REPAIR PARTS IAW SRM 51-20-01, APPLIED PRIMER ON REPAIR IAW SOPM 20-44-04. INSTALLED REPAIR IAW SRM 55-10-01-2R-11. APPLIED TOP COAT IAW AMM 51-21-99. INSTALLED HORIZONTAL STAB L/E PANEL AND STAB. CAP IAW AMM 27-41-21-400-801, AMM 55-10-00-400-801. CAT.B REPAIR.