What was found
FWD PIT TRANSITION PANEL RT SIDE HAS SPOTS OF CORROSION FROM BS 500A - 500D. GROUNDED - YES. REMOVED AND REPLACED FWD PIT TRANSITION PANEL IAW SRM 51-40-02-0G-0, W= 1" O= .040" R= .025" L= 1" D= .015".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT TRANSITION PANEL RT SIDE HAS SPOTS OF CORROSION FROM BS 500A - 500D. GROUNDED - YES. REMOVED AND REPLACED FWD PIT TRANSITION PANEL IAW SRM 51-40-02-0G-0, W= 1" O= .040" R= .025" L= 1" D= .015".