What was found
FWD PIT TRANSITION PANEL HAS CORROSION BETWEEN BS 500 - 500D. GROUNDED - YES. REMOVED AND REPLACED FWD LT TRANSITION PANEL IAW SRM 51-40-02-0G-0. W:1 0:.040' R:.034 L:1 D:.006.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT TRANSITION PANEL HAS CORROSION BETWEEN BS 500 - 500D. GROUNDED - YES. REMOVED AND REPLACED FWD LT TRANSITION PANEL IAW SRM 51-40-02-0G-0. W:1 0:.040' R:.034 L:1 D:.006.