What was found
REF TC 33-055-00. DURING EMER LTS BATTERY CAP CHECK THE FOLLOWING LTS EXTINGUISHED BEFORE 15 MINUTES: AFT CEILING PNL AISLE LT, AFT ENTRY EXIT LOCATOR, AFT LEFT OVERDOOR EXIT LT, & AFT LEFT ESCAPE SLIDE LT. GROUNDED - YES. REPLACED BATTERY PACK ON PWR SUPPLY MODULE M1673, OPS CHECK OK. REF WDM 33-51-14-2 & AMM 33-51-06.