What was found
AFT CARGO PIT LT TRANSITION PANEL BS 727 - 847 HAS CORROSION. GROUNDED - YES. REMOVED CORROSION ORIGINAL MATERIAL 0.040, REMOVED 0.040, REMANINING 0.000, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED DAMAGED TRANSITION PANEL, FABRICATED NEW REPAIR, ALODINED, PRIMED, AND INSTALLED IAW SRM 53-00-53-2R-5.