What was found
FWD CARGO PIT LT TRANSITION PANEL BS 500 - 500I HAS CORROSION. GROUNDED - YES. REMOVED CORROSION ORIGINAL THICKNESS .040, REMOVED .040, REMAINING .000. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED DAMAGE TRANSITION PANEL, FABRICATED NEW REPAIR PARTS USING BAC 1496-444, PO: 1133815.1. ALODINED, PRIMED AND INSTALLED IAW SRM 53-00-53-2R-5.