What was found
FLOOR SUPPORT AT BS 947-967 RBL 24 HAS SEVERAL AERAS OF CORROSION. GROUNDED - YES. REMOVED CORROSION ON FLOOR SUPPORT AT BS 947-967, RBL 24, LOST .030" OF MATERIAL FOUND BEYOND LIMITS IAW SRM 53-70-51-1A-1, REMOVED AND REPLACED INTERCOSTAL. PO 1138081.1 IAW SRM 51-40-02 AND DWG 147A5650 REV A. FLOOR SUPPORT WAS REMOVED ON CUSTOMER CARD G2255361,