What was found
WHILE GAINING ACCESS TO REPLACE BONDED NUTPLATES AT BS 500J, FOUND RT BAFFLE CORRODED BETWEEN BS 500I - 500J. GROUNDED - YES. REMOVED CORROSION BETWEEN BS 500I - 500J, RT BAFFLE, ORIGINAL MATERIAL 0.020", REMOVED 0.020", L=0.500", W=0.500" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. ACCOMPLISHED REPAIR 1, SECTION 43, FUSELAGE FWD CARGO COMPARTMENT FLOOR STRUCTURE, BAFFLE REPAIR WITH NEW BAFFLE AND REPAIR ANGLE, ITEM 2 IAW SRM 53-30-53-2R-1, REPAIR 1. CATEGORY A REPAIR.