What was found
CENTER AFT SPAR VAPOR BARRIER SKATE ANGLE CRACKED AT BS 661.95 RBL+9. GROUNDED - YES. REPAIRED UPPER BARRIER SKATE ANGLE AT BS 661.95 RBL+9. IAW SRM 57-10-10-2R-5, REPAIR 5, AND DWG 111A1000, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER AFT SPAR VAPOR BARRIER SKATE ANGLE CRACKED AT BS 661.95 RBL+9. GROUNDED - YES. REPAIRED UPPER BARRIER SKATE ANGLE AT BS 661.95 RBL+9. IAW SRM 57-10-10-2R-5, REPAIR 5, AND DWG 111A1000, REV A.